Using ISDN BRI 12-7
Configuring ISDN
Note – numberauto is off by default.
Setting the Number Type
To change the number type from the default manufacturer setting (so that you can, for
example, begin successfully to place outbound calls), use the following command:
Command> set isdn-numbertype 0|1|2|4
The new setting becomes effective immediately; it does not need to be saved to
nonvolatile RAM.
Enter this command without a number type value to display a list of all plan values
available, and the current setting.
Setting the Number Plan
To change the number plan from the default manufacturer setting (so that you can, for
example, begin successfully to place outbound calls), use the following command:
Command> set isdn-numberplan 0|1|2|7|8
The new setting becomes effective immediately; it does not need to be saved to
nonvolatile RAM.
Enter this command without a number plan value to display a list of all plan values
available, and the current setting.
Multilink PPP
Multilink PPP V.120 is supported on analog and ISDN interfaces. The PortMaster accepts
and detects both multiline load balancing and Multilink PPP connections. Multiple lines
can be used to increase bandwidth, either using Multilink PPP as defined in RFC 1717 or
using Lucent’s multiline load balancing.
To enable Multilink PPP, use the following command:
Command> set location Locname multilink on